Using a thermal imaging camera to locate moisture in a commercial flat roof friday february 28 2020.
Infrared imaging pitched roofs.
As a result of this difference the wet areas will hold heat energy longer than other areas providing the infrared inspector with a clear picture of the potentially.
The featured picture is an infrared of the below building.
When there is a leakage in a roof membrane the insulation inside the roof becomes wet.
Flat and pitched roofs are easily imaged by a drone much more quickly and safely than by a handheld unit.
Infrared inspections of roofing systems employ a thermal imager often referred to as an infrared camera to detect display and document thermal patterns across the surface of the roof.
Infrared roof moisture surveying is often difficult for thermographers to understand because of the many variety of roofs they encounter.
Infrared imaging services llc provides infrared roof inspection infrared roof testing roof thermal imaging roof moisture surveys of flat roofs to detect trapped moisture water leaks wet roof insulation and heat loss and more to the albany ny region ny capital region upstate ny vt.
They must also have a working knowledge of roof waterproofing roof insulation roof decks and roof.
If a leak occurs on a flat roof damage often goes unnoticed for considerable time as water penetrates and soaks the decking and underlying insulation.
The wet insulation has a higher thermal mass than the rest of the dry roof structure.
Infrared moisture surveys give contractors and inspectors the ability to see what is happening under your roof s membrane without having to damage your roof system.
This can lead to expensive damage from the rot which often develops and if left can weaken the roof structure.
Images produced by the drones showing the full extent of damage to the entire roof can make the repair or replace decision easier and more accurate.
Thermal imaging cameras can create detailed maps of commercial low slope roofs showing where excess moisture is trapped where the source of a leak may be or where there is soaked or compromised insulation.
Thermal imaging has been used since the 1970s to help determine if your facility needs a total roof replacement or if your facility roof can be repaired in the damaged areas.
If the image quality is not acceptable on a particular building roof early in the night they can return at different times during the night in order to image the building or many.
Roof system x ray sort of read on a roof system x ray or better known as an infrared of your roof system performed with a drone can be both cost effective and eye opening.
Roofing professionals have been using thermal imaging cameras for years to pinpoint water intrusion find moisture beneath the.
Roof inspections have become one of the most common applications for thermal imaging drones.
Drone infrared imaging flew about 80 off the ground to capture the below image.